FFRPG2Header
FFRPG2HeaderMobile

Home  /  Products  /  Indoor  /  Retrofit Kit  /  FFRP G2

LED Lensed Industrial Retrofit Kit

Part of the FormFocus product line, the FFRP G2 is a custom fit retrofit kit designed for existing 4-foot or 8-foot industrial-style louvered luminaires. Specifications of the existing fixture is required to ensure proper fit. A new industrial luminaire with a similar appearance, the FFLP G2, is also available (view FFLP G2 product page here). The FFRP G2's lift and shift design allows for quick and easy installation in a matter of just a few minutes. The frosted diffuser is optimized to balance efficiency and aesthetics. The tray is precision brake formed from cold rolled steel, with a matte white finish. Every FFRP G2 is made in the USA - in our Henderson, NC facility, utilizing mostly domestic and some foreign components.

Click to download (.pdf):
FormFocus FFRP G2 4' 
FormFocus FFRP G2 8'
Click to download (.zip):
FormFocus FFRP G2

  • Applications: Custom fit for 4-foot or 4-foot industrial-style louvered luminaires. Specifications of existing fixture required to ensure proper fit.
  • Lumen Output: From about 2,000 lm up to nearly 20,300
  • Max Lumens Per Watt: 148.3
  • Size Options: 4-foot, 8-foot
  • Predicted L70 Lifetime: 129,000 hours (calculated)
  • Warranty: 5 year limited system warranty. 10-year extended warranty available on specific models
  • Re-BoardABILITY: Every FFRP G2 is upgradeable. Boards and drivers can easily be swapped out for upgrade in a matter of minutes. Learn more about Re-Boardability here.
  • Certifications: UL 1598 listed for US and Canada, suitable for damp locations
  • Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components. BAA compliant options are available

Click to download (.pdf):
FFRP G2 4'
FFRP G2 8'

cULus-MiA-BAA-90CRI-10yr-2023

Note: Table scrolls horizontally
Catalog #
SizeLumensWattsLPWCRI / Color TempVoltages AvailablePredicted L70 Lifetime
FFR P G2 4 SL UV FA 9304-foot2,012.715.1132.990 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SL UV FA 9354-foot2,021.115.1133.590 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SL UV FA 9404-foot2,069.215.1136.690 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SL UV FA 9504-foot2,069.215.1136.690 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VL UV FA 9304-foot2,957.821.4138.190 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VL UV FA 9354-foot2,970.321.4138.790 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VL UV FA 9404-foot3,040.821.4142.090 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VL UV FA 9504-foot3,040.821.4142.090 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 LW UV FA 9304-foot3,964.328.4139.790 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 LW UV FA 9354-foot3,981.028.4140.390 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 LW UV FA 9404-foot4,075.628.4143.690 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 LW UV FA 9504-foot4,075.628.4143.690 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 MD UV FA 9304-foot4,944.235.2140.590 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 MD UV FA 9354-foot4,965.035.2141.190 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 MD UV FA 9404-foot5,083.035.2144.590 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 MD UV FA 9504-foot5,083.035.2144.590 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 HI UV FA 9304-foot5,947.243.5136.890 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 HI UV FA 9354-foot5,972.343.5137.490 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 HI UV FA 9404-foot6,114.143.5140.690 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 HI UV FA 9504-foot6,114.143.5140.690 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VH UV FA 9304-foot7,865.056.8138.490 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VH UV FA 9354-foot7,898.256.8139.090 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VH UV FA 9404-foot8,085.856.8142.390 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 VH UV FA 9504-foot8,085.856.8142.390 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SH UV FA 9304-foot9,873.974.4132.690 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SH UV FA 9354-foot9,915.674.4133.290 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SH UV FA 9404-foot10,151.174.4136.490 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 4 SH UV FA 9504-foot10,151.174.4136.490 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SL UV FA 9308-foot4,025.328.2142.790 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SL UV FA 9358-foot4,042.328.2143.390 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SL UV FA 9408-foot4,138.328.2146.790 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SL UV FA 9508-foot4,138.328.2146.790 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VL UV FA 9308-foot5,915.641.1144.190 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VL UV FA 9358-foot5,940.641.1144.790 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VL UV FA 9408-foot6,081.741.1148.190 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VL UV FA 9508-foot6,081.741.1148.190 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 LW UV FA 9308-foot7,928.655.0144.290 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 LW UV FA 9358-foot7,962.155.0144.890 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 LW UV FA 9408-foot8,151.255.0148.390 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 LW UV FA 9508-foot8,151.255.0148.390 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 MD UV FA 9308-foot9,888.469.2142.990 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 MD UV FA 9358-foot9,930.169.2143.690 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 MD UV FA 9408-foot10,165.969.2147.090 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 MD UV FA 9508-foot10,165.969.2147.090 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 HI UV FA 9308-foot11,894.585.1139.790 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 HI UV FA 9358-foot11,944.685.1140.390 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 HI UV FA 9408-foot12,228.385.1143.690 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 HI UV FA 9508-foot12,228.385.1143.690 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VH UV FA 9308-foot15,730.1113.7138.490 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VH UV FA 9358-foot15,796.4113.7139.090 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VH UV FA 9408-foot16,171.6113.7142.390 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 VH UV FA 9508-foot16,171.6113.7142.390 CRI / 5000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SH UV FA 9308-foot19,747.9148.9132.690 CRI / 3000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SH UV FA 9358-foot19,831.1148.9133.290 CRI / 3500K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SH UV FA 9408-foot20,302.1148.9136.490 CRI / 4000K120-277V, 347V129,000 hours (calculated)
FFR P G2 8 SH UV FA 9508-foot20,302.1148.9136.490 CRI / 5000K120-277V, 347V129,000 hours (calculated)
Catalog #
Equivalency*
FFR P G2 4 SL UV FA 9301L F32 T8, NBF
FFR P G2 4 SL UV FA 9351L F32 T8, NBF
FFR P G2 4 SL UV FA 9401L F32 T8, NBF
FFR P G2 4 SL UV FA 9501L F32 T8, NBF
FFR P G2 4 VL UV FA 9302L F40 T12
FFR P G2 4 VL UV FA 9352L F40 T12
FFR P G2 4 VL UV FA 9402L F40 T12
FFR P G2 4 VL UV FA 9502L F40 T12
FFR P G2 4 LW UV FA 9302L F32 T8, NBF / 1L F54 T5HO
FFR P G2 4 LW UV FA 9352L F32 T8, NBF / 1L F54 T5HO
FFR P G2 4 LW UV FA 9402L F32 T8, NBF / 1L F54 T5HO
FFR P G2 4 LW UV FA 9502L F32 T8, NBF / 1L F54 T5HO
FFR P G2 4 MD UV FA 9303L F40 T12
FFR P G2 4 MD UV FA 9353L F40 T12
FFR P G2 4 MD UV FA 9403L F40 T12
FFR P G2 4 MD UV FA 9503L F40 T12
FFR P G2 4 HI UV FA 9303L F32 T8, NBF
FFR P G2 4 HI UV FA 9353L F32 T8, NBF
FFR P G2 4 HI UV FA 9403L F32 T8, NBF
FFR P G2 4 HI UV FA 9503L F32 T8, NBF
FFR P G2 4 VH UV FA 9302L F54 T5HO
FFR P G2 4 VH UV FA 9352L F54 T5HO
FFR P G2 4 VH UV FA 9402L F54 T5HO
FFR P G2 4 VH UV FA 9502L F54 T5HO
FFR P G2 4 SH UV FA 9303L F54 T5HO
FFR P G2 4 SH UV FA 9353L F54 T5HO
FFR P G2 4 SH UV FA 9403L F54 T5HO
FFR P G2 4 SH UV FA 9503L F54 T5HO
FFR P G2 8 SL UV FA 9302L F32 T8, NBF / 1L F96 T8
FFR P G2 8 SL UV FA 9352L F32 T8, NBF / 1L F96 T8
FFR P G2 8 SL UV FA 9402L F32 T8, NBF / 1L F96 T8
FFR P G2 8 SL UV FA 9502L F32 T8, NBF / 1L F96 T8
FFR P G2 8 VL UV FA 9301L F96 T8HO
FFR P G2 8 VL UV FA 9351L F96 T8HO
FFR P G2 8 VL UV FA 9401L F96 T8HO
FFR P G2 8 VL UV FA 9501L F96 T8HO
FFR P G2 8 LW UV FA 9304L F32 T8, NBF / 2L F54 T5HO / 2L F96 T8
FFR P G2 8 LW UV FA 9354L F32 T8, NBF / 2L F54 T5HO / 2L F96 T8
FFR P G2 8 LW UV FA 9404L F32 T8, NBF / 2L F54 T5HO / 2L F96 T8
FFR P G2 8 LW UV FA 9504L F32 T8, NBF / 2L F54 T5HO / 2L F96 T8
FFR P G2 8 MD UV FA 9302L F96 T8HO
FFR P G2 8 MD UV FA 9352L F96 T8HO
FFR P G2 8 MD UV FA 9402L F96 T8HO
FFR P G2 8 MD UV FA 9502L F96 T8HO
FFR P G2 8 HI UV FA 9306L F32 T8, NBF / 2L F96 T8HO
FFR P G2 8 HI UV FA 9356L F32 T8, NBF / 2L F96 T8HO
FFR P G2 8 HI UV FA 9406L F32 T8, NBF / 2L F96 T8HO
FFR P G2 8 HI UV FA 9506L F32 T8, NBF / 2L F96 T8HO
FFR P G2 8 VH UV FA 9303L F96 T8HO
FFR P G2 8 VH UV FA 9353L F96 T8HO
FFR P G2 8 VH UV FA 9403L F96 T8HO
FFR P G2 8 VH UV FA 9503L F96 T8HO
FFR P G2 8 SH UV FA 9303L F96 T8HO
FFR P G2 8 SH UV FA 9353L F96 T8HO
FFR P G2 8 SH UV FA 9403L F96 T8HO
FFR P G2 8 SH UV FA 9503L F96 T8HO
*NOTE: Fixture equivalencies are estimates only and should be confirmed by photometric analysis or sample install to ensure adequate light levels are achieved.
Catalog #
ImageSpec Sheet
FFR P G2 4 SL UV FA 930View Download
FFR P G2 4 SL UV FA 935View Download
FFR P G2 4 SL UV FA 940View Download
FFR P G2 4 SL UV FA 950View Download
FFR P G2 4 VL UV FA 930View Download
FFR P G2 4 VL UV FA 935View Download
FFR P G2 4 VL UV FA 940View Download
FFR P G2 4 VL UV FA 950View Download
FFR P G2 4 LW UV FA 930View Download
FFR P G2 4 LW UV FA 935View Download
FFR P G2 4 LW UV FA 940View Download
FFR P G2 4 LW UV FA 950View Download
FFR P G2 4 MD UV FA 930View Download
FFR P G2 4 MD UV FA 935View Download
FFR P G2 4 MD UV FA 940View Download
FFR P G2 4 MD UV FA 950View Download
FFR P G2 4 HI UV FA 930View Download
FFR P G2 4 HI UV FA 935View Download
FFR P G2 4 HI UV FA 940View Download
FFR P G2 4 HI UV FA 950View Download
FFR P G2 4 VH UV FA 930View Download
FFR P G2 4 VH UV FA 935View Download
FFR P G2 4 VH UV FA 940View Download
FFR P G2 4 VH UV FA 950View Download
FFR P G2 4 SH UV FA 930View Download
FFR P G2 4 SH UV FA 935View Download
FFR P G2 4 SH UV FA 940View Download
FFR P G2 4 SH UV FA 950View Download
FFR P G2 8 SL UV FA 930View Download
FFR P G2 8 SL UV FA 935View Download
FFR P G2 8 SL UV FA 940View Download
FFR P G2 8 SL UV FA 950View Download
FFR P G2 8 VL UV FA 930View Download
FFR P G2 8 VL UV FA 935View Download
FFR P G2 8 VL UV FA 940View Download
FFR P G2 8 VL UV FA 950View Download
FFR P G2 8 LW UV FA 930View Download
FFR P G2 8 LW UV FA 935View Download
FFR P G2 8 LW UV FA 940View Download
FFR P G2 8 LW UV FA 950View Download
FFR P G2 8 MD UV FA 930View Download
FFR P G2 8 MD UV FA 935View Download
FFR P G2 8 MD UV FA 940View Download
FFR P G2 8 MD UV FA 950View Download
FFR P G2 8 HI UV FA 930View Download
FFR P G2 8 HI UV FA 935View Download
FFR P G2 8 HI UV FA 940View Download
FFR P G2 8 HI UV FA 950View Download
FFR P G2 8 VH UV FA 930View Download
FFR P G2 8 VH UV FA 935View Download
FFR P G2 8 VH UV FA 940View Download
FFR P G2 8 VH UV FA 950View Download
FFR P G2 8 SH UV FA 930View Download
FFR P G2 8 SH UV FA 935View Download
FFR P G2 8 SH UV FA 940View Download
FFR P G2 8 SH UV FA 950View Download

FFRP8ftPNGweb

Lift and shift

The FFRP G2 utilizes a "lift and shift" design concept, which allows it to quickly and easily be installed in the field. The kit ships with the LED drivers and boards installed on the tray. With the original lamps and ballasts removed, the retrofit unit is hung on one side of the existing housing. Safety tethers on both ends of the kit (two for the 4-footer, four for the 8-footer) are screwed into the existing housing for added security. The installer wires the driver to the existing power via a quick-disconnect before swinging the kit around to attach the other side. The whole process takes just a few minutes.

FFRP8ftPNGweb

Lift and shift

The FFRP G2 utilizes a "lift and shift" design concept, which allows it to quickly and easily be installed in the field. The kit ships with the LED drivers and boards installed on the tray. With the original lamps and ballasts removed, the retrofit unit is hung on one side of the existing housing. Safety tethers on both ends of the kit (two for the 4-footer, four for the 8-footer) are screwed into the existing housing for added security. The installer wires the driver to the existing power via a quick-disconnect before swinging the kit around to attach the other side. The whole process takes just a few minutes.