Germicidal Air Chamber with Down Light
The UVFocus GAB-C provides combines airborne disinfection with energy efficient LED down lighting in a 2x2 or 2x4 grid ceiling. The rear of the GAB-C is a germicidal air chamber that utilizes 254nm T8 UVC lamps to provide anti-viral and anti-bacterial disinfection. Air is pulled into the chamber via three center fans. Inside the chamber, air is dosed with UVC, which works to kill or inactivate airborne pathogens including viruses, bacteria, fungi, yeast and molds. Cleansed air is then recirculated back into the room. Because the UVC light is confined in the rear chamber, there is no exposure to the room below, making the GAB-C perfectly safe to use in occupied spaces. UVC at 254nm is effective against viruses and bacteria - including MRSA, C. Difficile, Salmonella, E. Coli - as well as mold, fungus, and odors. On the front of the GAB-C, two rows of energy efficient LEDs provide general illumination into the space below. A version without the down light is available - the GAB.
Note: UVFocus products are designed utilizing proven germicidal and antibacterial technology. UVC 254nm products work to deactivate most common viruses (as well as bacteria, molds and yeasts), and 405nm near-UV products are shown to substantially reduce bacterial presence. While these products can be considered disinfecting products, they should be used in conjunction with standard, proper disinfecting cleaning procedures to have the greatest impact for maintaining a clean environment. Successful UV disinfection requires a systems approach taking into account dose, optics and safety relevant to the specific application. Please consult with factory any questions or concerns. Please visit our UVFocus Safety page (link below) to learn more information.
For any inquiries about this product, email us at [email protected], or use the inquiry form at the bottom of this page. You can also call us toll-free at 1-866-UVFOCUS.
- Applications:Â Suitable for most commercial and institutional applications: office, retail, classrooms, healthcare facilities
- Lumen Output (down light): From 2,200 in the 2x2 to 9,500+ in the 2x4
- Max Lumens Per Watt (down light): 155.1
- Predicted L70 Lifetime (down light): Up to 189,000 hours (calculated)
- Size Options: 2x2 and 2x4
- Warranty: 3 year limited system warranty (excludes lamps). Lamps covered under manufacturer warranty
- Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components
GAB-C Down Light Performance
Catalog # | Watts | Lumens | LPW | CRI / Color Temp | Voltages Available | L70 Lifetime |
---|---|---|---|---|---|---|
GAB-C 22 2 15 GUVT8 SL UV FA 830 | 18 | 2258 | 125.4 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 SL UV FA 835 | 18 | 2296 | 127.6 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 SL UV FA 840 | 18 | 2372 | 131.8 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 SL UV FA 850 | 18 | 2443 | 135.7 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 VL UV FA 830 | 26 | 3089 | 118.8 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 VL UV FA 835 | 26 | 3141 | 120.8 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 VL UV FA 840 | 26 | 3244 | 124.8 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 VL UV FA 850 | 26 | 3342 | 128.5 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 LW UV FA 830 | 32 | 4124 | 128.9 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 LW UV FA 835 | 32 | 4194 | 131.1 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 LW UV FA 840 | 32 | 4332 | 135.4 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 LW UV FA 850 | 32 | 4462 | 139.4 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 MD UV FA 830 | 36 | 4531 | 125.9 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 MD UV FA 835 | 36 | 4607 | 128 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 MD UV FA 840 | 36 | 4760 | 132.2 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 MD UV FA 850 | 36 | 4903 | 136.2 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 HI UV FA 830 | 46 | 6105 | 132.7 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 HI UV FA 835 | 46 | 6208 | 134.9 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 HI UV FA 840 | 46 | 6413 | 139.4 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 22 2 15 GUVT8 HI UV FA 850 | 46 | 6605 | 143.6 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SL UV SF FA 830 | 23 | 3145 | 136.8 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SL UV SF FA 835 | 23 | 3198 | 139.1 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SL UV SF FA 840 | 23 | 3304 | 143.7 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SL UV SF FA 850 | 23 | 3403 | 148 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VL UV SF FA 830 | 28 | 3784 | 135.1 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VL UV SF FA 835 | 28 | 3848 | 137.4 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VL UV SF FA 840 | 28 | 3975 | 142 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VL UV SF FA 850 | 28 | 4094 | 146.2 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 LW UV SF FA 830 | 32 | 4237 | 132.4 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 LW UV SF FA 835 | 32 | 4308 | 134.6 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 LW UV SF FA 840 | 32 | 4451 | 139.1 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 LW UV SF FA 850 | 32 | 4584 | 143.3 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 ML UV SF FA 830 | 36 | 4672 | 129.8 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 ML UV SF FA 835 | 36 | 4751 | 132 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 ML UV SF FA 840 | 36 | 4908 | 136.3 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 ML UV SF FA 850 | 36 | 5055 | 140.4 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 MD UV SF FA 830 | 43 | 6163 | 143.3 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 MD UV SF FA 835 | 43 | 6266 | 145.7 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 MD UV SF FA 840 | 43 | 6473 | 150.5 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 MD UV SF FA 850 | 43 | 6667 | 155.1 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 HI UV SF FA 830 | 50 | 6946 | 138.9 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 HI UV SF FA 835 | 50 | 7062 | 141.2 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 HI UV SF FA 840 | 50 | 7296 | 145.9 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 HI UV SF FA 850 | 50 | 7515 | 150.3 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VH UV SF FA 830 | 60 | 8025 | 133.8 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VH UV SF FA 835 | 60 | 8025 | 136 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VH UV SF FA 840 | 60 | 8025 | 140.5 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 VH UV SF FA 850 | 60 | 8025 | 144.7 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SH UV SF FA 830 | 68 | 8866 | 130.4 | 80 CRI / 3000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SH UV SF FA 835 | 68 | 9015 | 132.6 | 80 CRI / 3500K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SH UV SF FA 840 | 68 | 9313 | 137 | 80 CRI / 4000K | 120-277V | Up to 189,000 hrs (calculated) |
GAB-C 24 4 15 GUV18 SH UV SF FA 850 | 68 | 9593 | 141.1 | 80 CRI / 5000K | 120-277V | Up to 189,000 hrs (calculated) |
Construction
The GAB-C features an aluminum housing with white powder coat finish. The germicidal chamber is constructed of durable aluminum. Inside the chamber, UVC reflective material is utilized to enhance energy fluence for rapid neutralization of pathogens. The lens is constructed of proprietary polycarbonate.