The UVFocus GAB-C provides combines airborne disinfection with energy efficient LED down lighting in a 2x2 or 2x4 grid ceiling. The rear of the GAB-C is a germicidal air chamber that utilizes 254nm T8 UVC lamps to provide anti-viral and anti-bacterial disinfection. Air is pulled into the chamber via three center fans. Inside the chamber, air is dosed with UVC, which works to kill or inactivate airborne pathogens including viruses, bacteria, fungi, yeast and molds. Cleansed air is then recirculated back into the room. Because the UVC light is confined in the rear chamber, there is no exposure to the room below, making the GAB-C perfectly safe to use in occupied spaces. UVC at 254nm is effective against viruses and bacteria - including MRSA, C. Difficile, Salmonella, E. Coli - as well as mold, fungus, and odors. On the front of the GAB-C, two rows of energy efficient LEDs provide general illumination into the space below. A version without the down light is available - the GAB.
Note: UVFocus products are designed utilizing proven germicidal and antibacterial technology. UVC 254nm products work to deactivate most common viruses (as well as bacteria, molds and yeasts), and 405nm near-UV products are shown to substantially reduce bacterial presence. While these products can be considered disinfecting products, they should be used in conjunction with standard, proper disinfecting cleaning procedures to have the greatest impact for maintaining a clean environment. Successful UV disinfection requires a systems approach taking into account dose, optics and safety relevant to the specific application. Please consult with factory any questions or concerns. Please visit our UVFocus Safety page (link below) to learn more information.
For any inquiries about this product, email us at uvfocus@lumenfocus.com, or use the inquiry form at the bottom of this page. You can also call us toll-free at 1-866-UVFOCUS.

  • Applications: Suitable for most commercial and institutional applications: office, retail, classrooms, healthcare facilities
  • Lumen Output (down light): From 2,200 in the 2x2 to 9,500+ in the 2x4
  • Max Lumens Per Watt (down light): 155.1
  • Predicted L70 Lifetime (down light): Up to 189,000 hours (calculated)
  • Size Options: 2x2 and 2x4
  • Warranty: 3 year limited system warranty (excludes lamps). Lamps covered under manufacturer warranty
  • Made in the USA, in our Henderson, NC facility, utilizing mostly domestic and some foreign components

DLC, MiA 0720

GAB-C Down Light Performance

Catalog #Watts LumensLPWCRI / Color TempVoltages AvailableL70 Lifetime
GAB-C 22 2 15 GUVT8 SL UV FA 830182258125.480 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 SL UV FA 835182296127.680 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 SL UV FA 840182372131.880 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 SL UV FA 850182443135.780 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 VL UV FA 830263089118.880 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 VL UV FA 835263141120.880 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 VL UV FA 840263244124.880 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 VL UV FA 850263342128.580 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 LW UV FA 830324124128.980 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 LW UV FA 835324194131.180 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 LW UV FA 840324332135.480 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 LW UV FA 850324462139.480 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 MD UV FA 830364531125.980 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 MD UV FA 83536460712880 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 MD UV FA 840364760132.280 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 MD UV FA 850364903136.280 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 HI UV FA 830466105132.780 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 HI UV FA 835466208134.980 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 HI UV FA 840466413139.480 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 22 2 15 GUVT8 HI UV FA 850466605143.680 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SL UV SF FA 830233145136.880 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SL UV SF FA 835233198139.180 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SL UV SF FA 840233304143.780 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SL UV SF FA 85023340314880 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VL UV SF FA 830283784135.180 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VL UV SF FA 835283848137.480 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VL UV SF FA 84028397514280 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VL UV SF FA 850284094146.280 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 LW UV SF FA 830324237132.480 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 LW UV SF FA 835324308134.680 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 LW UV SF FA 840324451139.180 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 LW UV SF FA 850324584143.380 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 ML UV SF FA 830364672129.880 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 ML UV SF FA 83536475113280 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 ML UV SF FA 840364908136.380 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 ML UV SF FA 850365055140.480 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 MD UV SF FA 830436163143.380 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 MD UV SF FA 835436266145.780 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 MD UV SF FA 840436473150.580 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 MD UV SF FA 850436667155.180 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 HI UV SF FA 830506946138.980 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 HI UV SF FA 835507062141.280 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 HI UV SF FA 840507296145.980 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 HI UV SF FA 850507515150.380 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VH UV SF FA 830608025133.880 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VH UV SF FA 83560802513680 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VH UV SF FA 840608025140.580 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 VH UV SF FA 850608025144.780 CRI / 5000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SH UV SF FA 830688866130.480 CRI / 3000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SH UV SF FA 835689015132.680 CRI / 3500K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SH UV SF FA 84068931313780 CRI / 4000K120-277VUp to 189,000 hrs (calculated)
GAB-C 24 4 15 GUV18 SH UV SF FA 850689593141.180 CRI / 5000K120-277VUp to 189,000 hrs (calculated)

GAB-C-0522-jpggreen

Construction

The GAB-C features an aluminum housing with white powder coat finish. The germicidal chamber is constructed of durable aluminum. Inside the chamber, UVC reflective material is utilized to enhance energy fluence for rapid neutralization of pathogens. The lens is constructed of proprietary polycarbonate.